      Technical Data MT8045 MT8145
      DC voltage
      Range 200mV, 2V, 20V, 200V, 1000V 300mV, 3V, 30V, 300V, 1000V
      Accuracy

      ±(0.05%rdg+3digits) 200mV~200V range

      ±(0.03%rdg+3digits)
      ±(0.1%rdg+5digits) 1000V range
      Input impedance 10MΩ 1000MΩ (300mV, 3V)
      10MΩ(other ranges)
      AC voltage (AC or AC+DC true rms)
      Range 200mV, 2V, 20V, 200V, 750V 300mV, 3V, 30V, 300V, 750V
      Accuracy 200mV range
      50Hz ~ 50kHz : ±(0.8%rdg+80digits)
      2V ~ 20V range
      50Hz ~ 20kHz: ±(0.8%rdg+80digits)
      200V range
      50Hz ~ 5kHz: ±(0.8%rdg+80digits)
      750V range
      50Hz ~ 400Hz: ±(1.0%rdg+50digits)

      300mV~300V range
      20~50Hz: ±(2.0%rdg+30digits)
      50Hz~10kHz: ±(0.5%rdg+30digits)
      10~20kHz: ±(1.0%rdg+50digits)
      20~ 30kHz: ±(5.0%rdg+50digits)
      30~50kHz: ±(10.0%rdg+50digits) 750V range
      50Hz~10kHz: ±(0.5%rdg+30digits)

      Input impedance 2MΩ 1MΩ series with 0.1μF
      DC current
      Range 20mA, 200mA, 2A, 20A 300mA, 10A
      Accuracy

      ±(0.35%rdg+10digits) 20mA,200mA range

      ±(0.1%rdg+3digits) 300mA range

      ±(0.8%rdg+10digits) 2A,20A range ±(1.5%rdg+3digits) 10A range
      AC current
      Range 200mA, 2A, 20A 300mA, 10A
      Accuracy 200mA range
      50Hz ~ 5kHz: ±(0.8%rdg+80digits)

      300mA range
      20~50Hz: ±(2.0%rdg+30digits)
      50Hz~10kHz: ±(0.5%rdg+30digits)
      10~20kHz: ±(1.0%rdg+80digits)
      20~ 30kHz: ±(5.0%rdg+80digits)

      2A~20A range
      50Hz ~ 400Hz: ±(1.0%rdg+50digits)

      10A range
      50Hz~2kHz: ±(1.5%rdg+30digits) 2~10kHz: ±(3%rdg+30digits)

      Resistance
      Range 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ, 20MΩ 300Ω, 3kΩ, 30kΩ, 300kΩ, 3MΩ, 30MΩ
      Accuracy

      ±(0.1%rdg+20digits) 200Ω range

      ±(0.05%rdg+3digits) 300Ω~300kΩ range

      ±(0.1%rdg+20digits) 200Ω range ±(0.1%rdg+3digits) 3MΩ range
      ±(0.4%rdg+5digits) 20MΩ range ±(0.5%rdg+3digits) 30MΩ range
      Capacitance
      Range 20nF, 2μF, 200μF  
      Accuracy

      ±(3.5%rdg+20digits) 20nF, 2μF range

       
      ±(5.0%rdg+30digits) 200μF range
      Frequency
      Range 20kHz, 200kHz 300Hz, 3kHz, 30kHz, 300kHz
      Accuracy ±(1.0%rdg+20digits) ±(0.05%rdg+2digits)
      hFE (PNP or NPN)
      Display 0 ~ 1000.0  
      Test condition Current is approx.10μA, Vce is approx.3V  
      Diode test
        Check the forward voltage of diode.
      Maximum forward voltage 2V,open voltage 2.8V
      Continuity beeper
      NMRR 60dB
      CMRR 120dB
      POWER SOURCE 110~127 VAC±10%, 220~240VAC±10%, 50Hz±2Hz / 60Hz±2Hz
      DIMENSIONS & WEIGHT 260mm×220mm×82mm
      Approx 1kg
      1029-00005